Injection specification
Injection speed: 0.05 ~ 7m/s
Speed setting: low speed, high speed, deceleration (all 10 sections of the field)
Deceleration function: standard configuration (servo valve control)
Automatic correction function: low speed, high speed, boost (standard)
Casting pressure: 1 points
control device
TOSCAST
Research and development on the basis of the company's processing center control system (die storage 64, with 32MB storage card)
Hydraulic servo control system
Injection speed control
Loop: hydraulic servo valve control, outlet shutoff control.
Control: real-time feedback control and learning control (learning control can make the actual injection speed curve correction for the set speed curve)
Features: 0 =>5.0m/sec high-speed acceleration time is 8 ~ 10msec
5 =>0 deceleration time is 8 ~ 10msec
Booster time control / casting pressure control
Loop: outlet throttle loop pressure cylinder mode
Control: preset + boost learning control (control valve of automatic regulation).
Preset pressure casting + learning control (accumulator pressure control).
Preset + learning control make the actual curve reaches the set curve.
Features: by learning control
From numerical specifications
Injection speed: 0.05 ~ 7m/s
Speed setting: low speed, high speed, deceleration (all 10)
Deceleration function: standard configuration (servo valve control)
Automatic correction function: low speed, high speed, boost (standard)
Casting pressure: 1 points
control device
TOSCAST
Research and development on the basis of the company's processing center control system (die storage 64, with 32MB storage card)
Hydraulic servo injection control system
Injection speed control
Loop: hydraulic servo valve control, export closure control.
Control: real-time feedback control and learning control (learning control can make the actual injection speed curve correction for the set speed curve)
Features: 0 =>5.0m/sec high speed acceleration time is 8 ~ 10msec
The deceleration time of 5 =>0 is 8 ~ 10msec
Rise time control / casting pressure control
Loop: outlet throttle loop pressure cylinder mode
Control: preset + boost learning control (control valve of automatic regulation).
Preset pressure casting + learning control (accumulator pressure control).
Preset + learning control make the actual curve reaches the set curve.
Features: by learning control (Toshiba patent) to boost and the casting pressure control to reach the set value + 3% error. Can predict filled end position control, thus inhibiting the slow pressurization time. Do not affect the injection control independently control
ACC (accumulator)
The piston ACC, simple circuit set pressure 13.5Mp 1ACC, using a special rigid seal can make its life to permanent.
(Toshiba patent) system to boost and the casting pressure control to reach within the set value + 3% error. Can predict filled end position control, thus inhibiting the slow pressurization time. Do not affect the injection control independently control
ACC (accumulator)
The piston ACC, simple circuit set pressure 13.5Mp 1ACC, using a special rigid seal can make its life to permanent.